Gold standard imaging

Researchers are developing a new type of ultra-sensitive medical imaging technique that works by shining a laser through the skin to detect tiny gold nanorods injected into the bloodstream.

Researchers at Purdue University have taken a step toward developing a new type of ultra-sensitive medical imaging technique that works by shining a laser through the skin to detect tiny gold nanorods injected into the bloodstream.

In tests with mice, the nanorods yielded images nearly 60 times brighter than conventional fluorescent dyes, including rhodamine, commonly used for a wide range of biological imaging to study the inner workings of cells and molecules.

Findings are detailed in a research paper that appeared online last week in Proceedings of the National Academy of Sciences. The paper was written by researchers in Purdue's Weldon School of Biomedical Engineering and the Department of Chemistry.

The nanorods might be used to develop an advanced medical imaging tool for the early detection of cancer, said Ji-Xin Cheng, an assistant professor of biomedical engineering.

The gold rods are about 20 nanometres wide and 60 nanometres long, or roughly 200 times smaller than a red blood cell.

Gold nanorods represent a possible way to overcome barriers in developing advanced medical imaging techniques that use light to analyse blood vessels and underlying tissues.

"One obstacle is that light in the visible spectrum does not pass through tissue very well," said Alexander Wei, an associate professor of chemistry who worked with Cheng and other Purdue researchers, including Philip S. Low, a professor of chemistry.

Imaging methods might be developed using laser pulses in longer wavelengths of light, beyond the visible range in a region of the spectrum called near infrared.

"There is a window of light in the near infrared, wavelengths from about 800 to 1,300 nanometres, which could be harnessed for new imaging technologies," Wei said.

Tiny gold rods with a certain "aspect ratio" of length to width shine brightly when illuminated by light in this spectral region. The gold nanorods are ideal for a type of imaging called "two-photon fluorescence," which provides higher contrast and brighter images than conventional fluorescent imaging methods.

Photons are the individual particles that make up light. In two-photon fluorescence, two photons hit the nanorod at the same time.

Because of the two-photon effect, the method might enable scientists to develop advanced "non-linear optical techniques" that provide better contrast than conventional technologies. Cheng is applying the two-photon fluorescence and other non-linear optical effects to develop imaging methods that provide improved contrast over conventional technologies.

The researchers injected the nanorods into mice and then took images of the tiny structures as the nanorods flowed through blood vessels in the animals' ears. Individual nanorods proved to be 58 times brighter than the two-photon fluorescence from a single rhodamine molecule. Within a half-hour after being injected, the nanorods could no longer be observed in the animals' blood, presumably because the rods had been filtered out of the blood by the kidneys.

"To be able to detect cells at an early stage of disease such as cancer, it is important to have a reliable technique that has sensitivity at the single-particle level," Wei said. "The gold nanorods demonstrate that Cheng's non-linear imaging methods are capable of this level of detection."

Purdue University photo courtesy of Weldon School of Biomedical Engineering and Department of Chemistry